Determining Minimum Flow Velocity for API 670 Shaft Vibration Probes

In centrifugal compressor projects, “minimum flow velocity” can refer to two different engineering limits. It may describe the process flow needed to keep the compressor away from surge, or it may be mistaken for a velocity requirement associated with shaft vibration probes. These are separate issues and should not be combined during design review.

API 670 primarily addresses machinery protection systems, including radial shaft vibration, axial position, speed, phase reference and related monitoring functions. An eddy-current probe measures the movement of a conductive shaft relative to the probe tip; it does not require a defined gas velocity across its face. The process minimum-flow calculation belongs to compressor performance and anti-surge control.

Design question Main variable Typical reference point Consequence of an error
Minimum compressor flow Gas mass or volumetric flow Compressor map and surge control line Surge, instability or mechanical damage
Flow velocity in piping Flow rate and internal diameter Suction, discharge or recycle line Poor control response, erosion or noise
Shaft vibration measurement Probe gap and shaft displacement Bearing housing and shaft target Incorrect vibration amplitude or alarms
Probe installation Target material, runout and cable system API 670 protection circuit Unreliable trips and nuisance shutdowns

Separate Process Flow From Probe Measurement

For a pipe or compressor passage, average gas velocity is calculated from the operating flow and flow area:

[ V=\frac{Q}{A} ]

Here, (V) is average velocity, (Q) is actual volumetric flow and (A) is the internal flow area. If the available flow is expressed as mass flow, the gas density must first be applied:

[ Q=\frac{\dot{m}}{\rho} ]

The minimum acceptable compressor flow should normally be taken from the OEM performance map, with allowances for operating pressure, temperature, gas composition, recycle response and measurement uncertainty. It is usually expressed as a mass-flow or corrected-flow limit rather than a universal metres-per-second value.

An API 670 radial vibration probe is positioned with a controlled gap to the shaft. Its signal represents shaft displacement relative to the probe, commonly as peak-to-peak amplitude. Gas velocity in the compressor does not establish a minimum probe velocity. If a project specification uses that phrase, the engineering team should clarify whether it means compressor minimum flow, internal gas velocity, or shaft surface speed.

Apply API 670 To The Protection System

The relevant API 670 design checks include probe type, mounting arrangement, driver or conditioner compatibility, signal transmission, monitor channels, alarm logic and trip voting. The probe system must also account for shaft material, electrical runout, mechanical runout, probe linear range and the required measurement bandwidth.

Probe gap is particularly important. A gap outside the manufacturer’s recommended linear range can create an inaccurate DC bias voltage and reduce the available dynamic range. The final setting should be verified during commissioning rather than inferred from process-flow calculations.

For an Australian facility, this documentation may sit alongside an OEM package from Perth, Melbourne or Brisbane and a site machinery protection standard. API 670 can define the protection philosophy, while the compressor manufacturer’s manual and the project control narrative establish operating limits.

Calculate The Minimum Flow Limit Correctly

A practical calculation begins with the compressor map. Identify the surge line, then establish a control line with the required margin. The anti-surge controller should maintain sufficient flow through the compressor, often by opening a recycle or spillback valve when demand falls.

The selected limit must reflect the worst credible operating case. Check suction temperature, molecular weight, discharge pressure, guide-vane position, recycle-valve capacity and instrument response time. A minimum-flow alarm may be set above the trip or control threshold so operators and automatic logic have time to respond.

Velocity is still useful when checking piping. For example, a recycle line may need enough flow authority for rapid protection without creating excessive pressure loss, acoustic noise or erosion. The result depends on line diameter and gas conditions, so copying a velocity from another compressor is unreliable.

Verify Probe Location And Shaft Conditions

Vibration probes are generally installed close to the journal bearings and arranged in orthogonal radial directions. Their location should provide a clear view of the shaft target while avoiding casing distortion, oil films, magnetic effects and obstructions. Probe brackets must remain stiff under operating temperature and vibration.

The shaft surface should provide a suitable conductive target, with acceptable mechanical and electrical runout. Coupling details, thrust position, bearing clearance and thermal growth can affect the measured signal. These checks are independent of whether the compressor is handling natural gas, hydrogen-rich gas, air or refrigerant.

At a hot site near Gladstone or Karratha, thermal expansion can change clearances between the cold installation condition and normal operation. Commissioning records should therefore capture probe gap, bias voltage, baseline vibration and phase data at several stable load points.

Check Cabling, Calibration And Compliance

API 670 protection performance depends on the complete measurement chain, not just the probe tip. Extension cables, proximitor modules, junction boxes, barriers and monitor inputs must be compatible in length, impedance, temperature rating and hazardous-area application. Cable routing should limit electromagnetic interference and physical damage.

This is also where project teams may need specialist industrial cable products suited to demanding plant environments. In Australia, cable selection may need coordination with hazardous-area requirements, site electrical rules and state or territory work health and safety duties. A cable that works electrically may still be unsuitable for heat, hydrocarbons, ultraviolet exposure or mechanical impact.

Calibration should verify the monitor’s displayed amplitude, alarm setpoints, trip logic, channel voting and loss-of-signal response. Keep the calibration certificates, loop drawings and as-built probe dimensions in the machinery protection dossier.

Use Standards And Site Data Together

A controlled copy of the applicable API edition should be reviewed with the compressor datasheet, OEM vibration limits and project specifications. Engineering teams comparing API requirements with Australian project documentation can also consult the ANSI standards catalogue when related US or international standards are included in the procurement package.

Australian operators commonly work in SI units, quote equipment in Australian dollars and manage equipment across long distances between metropolitan workshops and remote plants. Those practical conditions make clear calculations and complete digital records especially valuable. A shutdown investigation in Sydney can involve drawings prepared in Melbourne, a compressor supplied through Perth and field records from the Pilbara.

The final design should state the minimum process flow, the associated control and trip thresholds, and the independent API 670 probe requirements. Documenting those as separate values prevents a misleading “minimum probe flow velocity” from entering the cause-and-effect matrix. Use the compressor map for anti-surge protection, and use probe-gap, runout and monitor verification for shaft vibration protection. Obtain the applicable standards and engineering records through Document Bays to support procurement, commissioning and compliance reviews.

Quick Inquiry

Questions about an order or a specific standard? Use our contact form.

Contact Us

Secure payment with SSL

Featured Products

ANSI/ASHRAE

ANSI/ASHRAE 149-2013

$17.63 Add to Cart
ANSI/HI

ANSI/HI 11.6-2012

$40.85 Add to Cart
ANSI/ASSE

ANSI/ASSE Z690 Package

$60.20 Add to Cart
ANSI/ASHRAE

ANSI/ASHRAE 113-2013

$17.63 Add to Cart
ANSI/HI

ANSI/HI 14.6-2011

$83.85 Add to Cart
ANSI/ALI

ANSI/ALI A14 Standards Set

$645.00 Add to Cart

About Standards Store

We provide industry standards and codes in PDF format for immediate download. Our catalog spans engineering, manufacturing, construction, and quality management — with documents from over 50 issuing bodies worldwide.

Learn More

Latest Additions

Recently added standards include AWS D14.4/D14.4M-2019, API RP 581-2019, ISO/IEC 17025:2017, RTCA DO-363, and IPC/ECA J-STD-002E. Visit the New Standards section for the complete list.

New Standards

Secure Payment

All transactions are protected with SSL encryption. We accept Visa, Mastercard, and PayPal. Use coupon codes at checkout for additional discounts on eligible items.

Payment Info

Standards Store is dedicated to making technical standards and codes accessible to professionals worldwide. Every document in our catalog is delivered as a PDF for immediate download — no shipping, no waiting. We serve engineers, quality assurance specialists, manufacturers, and contractors who rely on accurate, up-to-date standards for their work.

Browse by issuing organization, explore new additions, or check our specials for discounted titles.

For questions about an order or for information about our products, please use the contact form below. Select the appropriate subject — Customer Service for order inquiries or Webmaster for technical issues with the website.

We aim to respond promptly to all inquiries.

Send a Message