ANSI/ISA-62443-3-3 Security Risk Assessment for SIS Communications

Industrial control systems increasingly connect safety instrumented systems (SIS) with distributed control systems, remote engineering workstations, asset management platforms and plant networks. This connectivity can improve visibility and maintenance, yet it also creates pathways that may affect the confidentiality, integrity or availability of safety-related communications.

ANSI/ISA-62443-3-3 provides a structured set of system-level security requirements for industrial automation and control systems. For engineers, integrators and operators in Australia, it is a valuable reference when assessing cyber risks around process safety functions, shutdown logic, safety controllers, field devices and supporting infrastructure.

Why The Standard Matters

A safety instrumented system is designed to move a process to a safe state when defined hazardous conditions occur. Its primary purpose is functional safety, but its protective action can be undermined if an attacker blocks a trip signal, changes configuration data, disables diagnostics or interferes with communication between the logic solver and remote equipment.

ANSI/ISA-62443-3-3 helps organisations examine these risks through foundational requirements such as identification and authentication, use control, system integrity, data confidentiality, restricted data flow, timely response to events and resource availability. These requirements support a defensible security architecture without treating cybersecurity as a separate concern from process safety.

The standard is particularly relevant to facilities in the Pilbara, Gladstone, the Hunter Valley and other regions where process automation supports mining, LNG, chemicals, power generation and heavy manufacturing. A brief network interruption can have significant safety, production and maintenance consequences in a remote operation.

Connecting Cybersecurity With Functional Safety

Cybersecurity risk assessment should complement, rather than replace, a hazard and operability study, layer of protection analysis or safety integrity level assessment. In Australia, projects commonly align functional safety activities with IEC 61511 and its Australian adoption, AS IEC 61511. The security review adds questions about intentional misuse, unauthorised access and compromised equipment.

The assessment should map each important communication path. Examples include safety PLC links, engineering access, diagnostic channels, remote I/O, time synchronisation, historian connections and interfaces with the basic process control system. Engineers should document what data moves across each connection, which devices can initiate a session and what happens if messages are delayed, altered or lost.

Physical and mechanical performance can also influence the reliability of connected assets. For background on how manufacturing tolerances can affect rotating equipment behaviour, see this analysis of bearing variation. The same risk-based mindset applies: identify the deviation, determine its consequence and establish controls that can be verified.

Building A Security Risk Assessment

A useful assessment begins with an accurate asset inventory and network model. Record safety instrumented functions, controllers, I/O modules, communication protocols, switches, firewalls, remote access tools, software versions and maintenance interfaces. Include vendor connections and temporary equipment, as these are often overlooked during project handover.

The next stage is to identify threats and vulnerabilities for each zone and conduit. Consider malware, stolen credentials, insecure engineering laptops, unsupported operating systems, unauthorised configuration changes, denial-of-service events and loss of power or communications. Evaluate the possible effect on the safe operating state, including nuisance trips, failure to trip and incorrect process information.

ANSI/ISA-62443-3-3 is generally used with the broader 62443 series. The risk assessment and security level concept are supported by other parts of the series, while the 3-3 document translates the required protection into system-level requirements. This makes it useful for procurement specifications, design reviews, factory acceptance testing and operational audits.

Security Levels And Communication Controls

The standard defines security levels that describe the capability of a system to resist increasingly capable threats. The target security level should be justified by the risk assessment, not selected as a generic label for the whole plant. A safety controller may require stronger protection than a low-impact monitoring device, while a remote maintenance conduit may need special controls because it crosses a trust boundary.

Communication protections can include network segmentation, deny-by-default rules, authenticated access, least-privilege permissions, secure configuration management, monitoring and tested recovery procedures. Controls should be selected with care so that security mechanisms do not introduce unacceptable latency, common-cause failure or reduced availability in a safety function.

Operators should also verify how controls behave during abnormal conditions. A firewall rule update, certificate expiry, failed authentication service or overloaded switch must not create an unexpected loss of safety capability. Where a control cannot be applied directly to a legacy device, compensating measures may include an isolated zone, jump server, strict physical access and continuous monitoring.

Applying The Requirements In Australia

Australian operators must consider the Security of Critical Infrastructure Act where the facility and asset fall within relevant critical infrastructure obligations. Requirements may also be shaped by state-based safety regulators, corporate engineering practices, contract conditions and customer requirements. The assessment should clearly record which obligations apply and who owns each action.

Local operating realities matter. A site in Western Australia may rely on fly-in fly-out personnel and long supply chains for replacement hardware. A Queensland processing plant may have contractors arriving for a planned shutdown, while a New South Wales facility may share systems with corporate or operational technology teams in Sydney or Melbourne. These conditions affect patching, access approvals, spares, incident response and recovery time.

Documentation should be practical for the people who operate the plant. Clear network drawings, approved configuration baselines, communication failure procedures and contact details are more useful than a report that remains in a project folder. Standards work should also fit the wider engineering system; for example, fabrication and structural projects may rely on documents such as the bridge welding code, showing why controlled standards access matters across Australian industry.

Making The Assessment Actionable

The strongest assessment connects each risk to a requirement, an accountable person, evidence and a review date. It should be updated after major modifications, new remote access arrangements, cybersecurity incidents, changes to the SIS application or replacement of obsolete equipment.

Useful actions include:

  • Define SIS zones and communication conduits using current engineering drawings.
  • Assign target security levels according to documented process and cyber risk.
  • Test authenticated access, backup restoration, alarm handling and configuration recovery.
  • Separate vendor maintenance access from permanent control-system connectivity.
  • Keep software, firmware, certificates and approved configurations under change control.

A downloadable copy of ANSI/ISA-62443-3-3 can support detailed design reviews, tender documents, compliance checks and internal training. Review the applicable edition and related functional safety requirements before using it as a project specification, then make the resulting controls visible to engineering, operations, maintenance and cybersecurity teams.

Use the standard as a working reference rather than a paper exercise. Obtain the relevant PDF from Document Bays, map its requirements to your SIS communications and retain objective evidence that each protection has been designed, tested and maintained.

Quick Inquiry

Questions about an order or a specific standard? Use our contact form.

Contact Us

Secure payment with SSL

Featured Products

ANSI/ASHRAE

ANSI/ASHRAE 149-2013

$17.63 Add to Cart
ANSI/HI

ANSI/HI 11.6-2012

$40.85 Add to Cart
ANSI/ASSE

ANSI/ASSE Z690 Package

$60.20 Add to Cart
ANSI/ASHRAE

ANSI/ASHRAE 113-2013

$17.63 Add to Cart
ANSI/HI

ANSI/HI 14.6-2011

$83.85 Add to Cart
ANSI/ALI

ANSI/ALI A14 Standards Set

$645.00 Add to Cart

About Standards Store

We provide industry standards and codes in PDF format for immediate download. Our catalog spans engineering, manufacturing, construction, and quality management — with documents from over 50 issuing bodies worldwide.

Learn More

Latest Additions

Recently added standards include AWS D14.4/D14.4M-2019, API RP 581-2019, ISO/IEC 17025:2017, RTCA DO-363, and IPC/ECA J-STD-002E. Visit the New Standards section for the complete list.

New Standards

Secure Payment

All transactions are protected with SSL encryption. We accept Visa, Mastercard, and PayPal. Use coupon codes at checkout for additional discounts on eligible items.

Payment Info

Standards Store is dedicated to making technical standards and codes accessible to professionals worldwide. Every document in our catalog is delivered as a PDF for immediate download — no shipping, no waiting. We serve engineers, quality assurance specialists, manufacturers, and contractors who rely on accurate, up-to-date standards for their work.

Browse by issuing organization, explore new additions, or check our specials for discounted titles.

For questions about an order or for information about our products, please use the contact form below. Select the appropriate subject — Customer Service for order inquiries or Webmaster for technical issues with the website.

We aim to respond promptly to all inquiries.

Send a Message